Installation of linear joint and cavity barriers (open state and full fill) seals refresher
Overview
Duration
1 day of 6 learning hours. If e-learning only, the duration is to be at least 50% of this.
Purpose/scope
The purpose of Installation of linear joint and cavity barriers (open state and full fill) seals refresher course is for delegates who have previously passed the Installation of linear joint and cavity barriers (open state and full fill) seals course or subsequent refresher course and can provide proof of attendance.
Occupational relevance
Training delivered against this standard would be relevant to the following occupational group(s):
- operative and craft.
Delegates pre-requisites
Delegates must have successfully completed Installation of linear joint and cavity barriers (open state and full fill) seals within the last 36 months.
Instruction/supervision
As a minimum, course trainers must be able to demonstrate that, in relation to this standard, they have:
- an award in education and training (or equivalent, as per requirements for approved training organisations)
- successfully completed training to this standard
- at least 2 years relevant industrial experience
- a verifiable CV.
Delivery
Delivery may be in an on or off the job environment.
All materials and equipment must be of a suitable quality and quantity for delegates to achieve learning outcomes and must comply with relevant legislation.
The class size and delegate/trainer ratio must allow training to be delivered in a safe manner and enable delegates to achieve the learning outcomes.
The following delivery methods may be used in the delivery of this standard:
- classroom.
This standard is considered to contain 51% or more practical training.
This standard is considered to be set at an intermediate level.
Assessment
Methods of assessment considered appropriate for training delivered against this standard are:
For the successful completion of training, delegates must complete an end of course practical assessment or knowledge test that measures all learning outcomes and has a pass or fail criteria.
Where this training is assessed using multiple-choice questions, a minimum of 10 questions must be asked and delegates are required to achieve an overall pass mark of at least 85%.
Quality assurance
Assured
Quality assurance against this standard will require initial approval of the training organisation and their content mapped to the standard.
CITB will also conduct an approval intervention, either desk-based or centre visit, to ensure the training organisation can meet the requirements of the training standard.
Approved training organisations (ATOs) will be required to present information on records of training and assessment upon request to CITB for desk-based analysis. They will also be visited annually by the CITB quality assurance team.
Renewal
Refresher every 3 years.
Classification
Mandatory Refresher.
Keywords
Cavity Barriers, Passive Fire Stopping, Cavity Seals, Ventilated cavity barriers, Linear joint seals, Fire resistant construction joints, Construction movement and control joints, Fire rated soft joints, Fire rated head joints, Fire rated expansion joints, Open state cavity barriers.
Approval date
June 2021
Review cycle
On request or 3 years from approval date.
Learning outcomes to be refreshed
The delegate will be able to: |
Additional guidance to support learning outcome |
---|---|
select the appropriate system to be used in all cavity and linear joint seals projects and record the installation process as part of the Golden Thread cascade of information. |
• ASFP On-site guide to installing fire-stopping • ASFP Advisory Note 7: Version 19-05-2014 Horizontal Linear Gap Seals Used In Curtain Walling Systems BB7 video presentation Cavity Barriers in External Wall Systems |
describe the role of fire compartments and their role in the wider fire protection of the building |
|
describe what the role of the linear joint and cavity fire seal is |
|
describe the relevant legislation and guidance associated with linear joint and cavity barrier seals |
|
describe the actions that must be undertaken before installing tested cavity and linear joint seal systems:
|
|
undertake and describe the process and record the installing generic fire seal systems:
|
|
undertake on completion of the installation of cavity and linear gap seals:
|
|
undertake on completion of the installation of service penetration seals:
|
|
Additional information about this standard
Fire safety: Approved Document B.
Building Regulation in England & Wales and Northern Ireland and Scotland covering fire safety matters within and around buildings.
The ASFP publication, Ensuring Best Practice for Passive Fire Protection in Buildings,
Regulatory Reform Order 2005.