Preparation of roof decking for existing roof
Overview
Duration
½ day of 3 learning hours
Purpose/scope
The purpose of this standard is to provide the delegate with the knowledge to prepare a roof deck substrate for installation of a single ply roof.
Scope:
- safe access and working practices on different types of roof
- temporary protection methods for a roof
- working with other trades
- how to prepare roof deck substrates including fixings, vapour control layers, and insulation for:
- profiled metal
- in-situ concrete
- screed over pre-cast concrete
- timber panels
- woodwool slabs
- existing built-up and mastic asphalt roof for an overlay
- materials: handling, storage, and estimating
- main legislation, codes of practice, standards, and guidance
Occupational relevance
Training delivered against this standard would be relevant to the following occupational group(s):
- operative and craft
- supervision
Delegates pre-requisites
There are no delegate pre-requisites as part of this standard, however a basic knowledge of single ply roofing terminology and techniques would be beneficial.
Instruction/supervision
As a minimum, course trainers must be able to demonstrate that, in relation to this standard, they have:
- an award in education and training (or equivalent, as per requirements for approved training organisations)
- successfully completed training to this standard
- at least 2 years relevant industrial experience
- a verifiable CV
Delivery
Delivery may be in an on or off the job environment.
All materials and equipment must be of a suitable quality and quantity for delegates to achieve learning outcomes and must comply with relevant legislation.
The class size and delegate/trainer ratio must allow training to be delivered in a safe manner and enable delegates to achieve the learning outcomes.
The following delivery methods may be used in the delivery of this standard:
- classroom
This standard is considered to contain 51% or more theoretical learning.
This standard is considered to be set at an intermediate level.
Assessment
Methods of assessment considered appropriate for training delivered against this standard are:
For the successful completion of training, delegates must complete an end of course practical assessment or knowledge test that measures all learning outcomes and has a pass or fail criteria.
Where this training is assessed using multiple-choice questions, a minimum of 10 questions must be asked and delegates are required to achieve an overall pass mark of at least 80%.
Quality assurance
Assured
Quality assurance against this standard will require initial approval of the training organisation and their content mapped to the standard.
CITB will also conduct an approval intervention, either desk-based or centre visit, to ensure the training organisation can meet the requirements of the training standard.
Approved training organisations (ATOs) will be required to present information on records of training and assessment upon request to CITB for desk-based analysis. They will also be visited annually by the CITB quality assurance team.
Renewal
There are no mandatory renewal or recommended refresher requirements for this standard.
Classification
Lifetime
(Please note standards using this classification will only be grant aided once per delegate)
Approval date
January 2022
Review cycle
On request or 3 years from approval date.
Learning outcomes to be refreshed
The delegate will be able to:
Learning outcomes The delegate will be able to: |
Additional guidance to support learning outcome
|
Describe safe access and working practices on different types of roof |
BS 6229:2018 Flat roofs with continuously supported flexible waterproof coverings. Code of practice
BS 8217:2005 Reinforced bitumen membranes for roofing. Code of practice
Photos/illustrations/videos Manufacturer’s operating and maintenance manuals Good and bad practice |
Describe temporary protection methods for a roof deck |
BS 6229:2018 Flat roofs with continuously supported flexible waterproof coverings. Code of practice
BS 8217:2005 Reinforced bitumen membranes for roofing. Code of practice
Photos/illustrations/videos Manufacturer’s operating and maintenance manuals Good and bad practice |
Describe how to work with other trades |
BS 6229:2018 Flat roofs with continuously supported flexible waterproof coverings. Code of practice
BS 8217:2005 Reinforced bitumen membranes for roofing. Code of practice
Photos/illustrations/videos Manufacturer’s operating and maintenance manuals Good and bad practice |
Describe how to prepare roof deck substrates including fixings, vapour control layers, and insulation for:
|
BS 6229:2018 Flat roofs with continuously supported flexible waterproof coverings. Code of practice
BS 8217:2005 Reinforced bitumen membranes for roofing. Code of practice
Photos/illustrations/videos Manufacturer’s operating and maintenance manuals Good and bad practice |
Describe materials: handling, storage, and estimating |
|
List the main types of information for safe working |
Safety legislation (H&SAWA, COSHH, PUWER, LOLER, Work at Height), HSE guidance, manufacturer’s documents, British/EN/ISO Standards, codes of practice, association guidance, building regulations, SDS sheets, company procedures, risk assessments |
Additional information about this standard
Single Ply Roofing Association (SPRA)
SPRA sets the design standards for single ply roofing in the UK. You can view the following free guides on the SPRA website.
- Design guide for single ply roofing
- Acoustic control
- Adhesives
- Falls and drainage for single ply roofs (S10-10)
- Guarantees – Guidance for clients and designers (S4-17)
- Homeowners guide 2017 (S12-17)
- Membrane product substitution checklist (S3-17)
- Non-destructive testing of single ply membrane roofing coverings (S8-17)
- Protection of single ply membrane roofs-guidance and checklist (SDG13-17)
- Recycling scoping study (2017)
- Safety – Design considerations for reduced risk (S5-17)
- Sealants in single ply roofing (S7-17)
- Ten reasons to specify SPRA contractor (S2-17)
- Welding guidance (S14-18)
- Wind load design requirements for single ply roofing (S11b-17)
- Wind loading – single ply roofing guide and checklist (S11a-16)
SPRA also publishes ‘Component quality schemes’ for materials and equipment. These take existing standards (BS and BS-EN) and apply specific levels of performance required in single ply applications:
- Expanded polystyrene insulation boards for inverted roofs (CQS2B-17)
- Expanded polystyrene insulation boards for roofing (CQS2A-17)
- Extruded polystyrene insulation boards for roofing (CQS3-17)
- Factory-manufactured single ply membrane gutters (CQS8-17)
- Fall protection anchor devices (CQS9-17)
- Mechanical fasteners for attachment of insulation and membranes (CQS5-17)
- Rock mineral wool insulation boards for roofing (CQS4-17)
- Roof access hatches (CQS7-17)
- Rooflights (CQS6-17)
- SPRA-IMA quality standards (CQS1-17)
- Vacuum insulated roof panels (VIPS) for roofing applications (CQS10-17)
British Flat Roofing Council
- Flat roofing: Design and good practice 1993
Training at height
- BS 8454:2006 Code of practice for delivery of training & education for work at height and rescue
Work at Height Safety Association
- View WAHSA technical guidance notes. These are a free resource, provided and maintained by WAHSA and its member companies for reference. They assist specifiers, managers, and end users of fall protection equipment.
Health and Safety Executive (HSE) Working at height guides
- Working at height
- Useful web links on working at height
- Health and safety in roof work
- Fragile roofs, safe working practices
- Inspecting fall arrest equipment made from webbing or rope
- PPE
- Safe use of work equipment (PUWER)
- Control of substances hazardous to health (COSHH)
British-European standards
You can view British and European standards on the BSI website
Note: Currently there are no British standards that cover polymeric single ply waterproofing membranes.
- BS 476-3: 2004. Fire tests on building materials and structures. Classification and test methods for roofs
- BS-EN 1991-1-2 6399: Part 2:1997 Code of practice for wind loads
- BS-EN 1991-1-4: 2005 + A1:2010 Eurocode 1. Actions on structures. General actions. Wind actions
- BS 4841-4: 2006. Rigid polyurethane (PUR) and polyisocyanurate (PIR) products for building end-use applications. Specification for laminated insulation boards (roofboards) with auto-adhesively or separately bonded facings for use as roofboard thermal insulation under non-bituminous single-ply roofing membranes
- BS 6399-2:1997. BS6399-2: 1997 Loading for buildings. Part 2: Code of practice for wind loads
- BS 6229: 2003 Code of practice for flat roofs with continuously supported coverings
- BS 8217: 2005 Reinforced membranes for roofing - Code of practice
- BS 8437: 2005 Code of practice for select/use/maintain personal protection systems and equipment
- BS 8454: 2006 Code of practice for delivery of training & education for work at height and rescue
- BS-EN 12056-3: 2001 Part 3 Gravity drainage systems in buildings. Roof drainage, layout & calcs
- BS-EN 13956: 2003 Flexible (plastic and rubber) sheets for roof waterproofing. Definitions/characteristics
- HB 10139:1997. Wind loading ready reckoner for BS 6399: Part 2: 1997
- DD CEN / TS 1187: 2012 Test methods for external fire exposure to roofs
Legislation
See relevant legislation
- The Work at Height Regulations (WHR) 2005
- Statutory Rules of Northern Ireland
- The Building (Scotland) Regulations 2004
- Building and Buildings, England and Wales: The Building Regulations 2010
- Control of Substances Hazardous to Health Regulations (COSHH) 2002
- Health and Safety at Work etc Act 1974
Related standards
- Building regulations and standards
- Application details of single ply roofing
- Types of roof systems
- Thermal insulation for single ply roofing
- Tools and equipment used with single ply roofing
- Testing and repair
- Single ply roofing introduction
- Single ply roofing advanced
- Waterproofing membranes
- Design principles of single ply roofing
- Methods of attachment
- Waterproof membrane roofing systems installation
How did we do today? Give feedback